Question:
What are the key coding guidelines for reporting bronchial valve procedures, transbronchial lung biopsies, and bronchial stent placement or revision?
Answer:
Code 31647 and add-on code +31651 report the insertion of bronchial valves at the time of the bronchoscopy procedure, while 31648 and add-on code +31649 report their removal.
Code +31632 is used to report transbronchial lung biopsy, each additional lobe, and should not be reported more than once regardless of how many biopsies are performed in the lobe.
Codes 31636–31638 are used for reporting the placement or revision of inserted stents. AMA states that +31637 should be reported in conjunction with 31636.